{"id":3209,"date":"2024-07-22T11:58:49","date_gmt":"2024-07-22T09:58:49","guid":{"rendered":"https:\/\/aircontech.eu\/railway-vehicles"},"modified":"2026-02-04T15:20:35","modified_gmt":"2026-02-04T14:20:35","slug":"railway-vehicles","status":"publish","type":"page","link":"https:\/\/aircontech.eu\/en\/railway-vehicles","title":{"rendered":"Railway vehicles"},"content":{"rendered":"<section  class=\"teasersection-image-text uk-padding-remove-top uk-padding-remove-bottom\">\n    <div class=\"uk-cover-container\">\n   <canvas width=\"1920\" height=\"577\"><\/canvas>\n   <img uk-cover uk-img=\"target: .teasersection-image-text\" data-src=\"https:\/\/aircontech.eu\/wp-content\/uploads\/2024\/07\/thermomanagement-schienenfahrzeuge.jpg\" data-srcset=\"https:\/\/aircontech.eu\/wp-content\/uploads\/2024\/07\/thermomanagement-schienenfahrzeuge.jpg 1920w, https:\/\/aircontech.eu\/wp-content\/uploads\/2024\/07\/thermomanagement-schienenfahrzeuge-300x125.jpg 300w, https:\/\/aircontech.eu\/wp-content\/uploads\/2024\/07\/thermomanagement-schienenfahrzeuge-1024x427.jpg 1024w, https:\/\/aircontech.eu\/wp-content\/uploads\/2024\/07\/thermomanagement-schienenfahrzeuge-768x320.jpg 768w, https:\/\/aircontech.eu\/wp-content\/uploads\/2024\/07\/thermomanagement-schienenfahrzeuge-1536x640.jpg 1536w, https:\/\/aircontech.eu\/wp-content\/uploads\/2024\/07\/thermomanagement-schienenfahrzeuge-1200x500.jpg 1200w\" sizes=\"(max-width: 1440px) 100vw, 1440px\" alt=\"Thermomanagement Schienenfahrzeuge\" \/>\n  <\/div>\n      <div class=\"teasersection-image-text_text-wrapper\">\n    <div class=\"uk-container uk-container-large\">\n      <div uk-grid>\n        <div class=\"uk-width-1-1\">\n          <span class=\"teasersection-image-text_text\">\n            Railway vehicles          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n        <\/section>\n<section  class=\"text-section\">\n  <div class=\"uk-container uk-container-large\">\n\n    <div uk-grid>\n\n      <div class=\"uk-width-1-1\">\n        <h1>We get thermal management on track<\/h1>\n<p>Thermal management systems are essential for the smooth operation of railway vehicles and track construction machines. By combining advanced HVAC systems, efficient coolant integration, intelligent software control and robust construction, we ensure that these vehicles operate reliably and in an environmentally-friendly manner under a wide range of conditions. These technologies not only contribute to operational safety and efficiency, but also support the fulfilment of strict environmental and fire protection requirements, such as those set out in EN 45545.<\/p>\n\n              <\/div>\n\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"section-headline\">\n  <h2 class=\"section-headline_headline uk-display-inline\">Battery tempering and heat pumps<\/h2>\n<\/section>\n<section  class=\"image-text-section\">\n  <div class=\"uk-container uk-container-large\">\n\n    <div uk-grid class=\"uk-flex uk-flex-middle\">\n      <div class=\"uk-width-1-2@m image-text-section_image uk-flex-first\">\n        <img uk-img=\"target: .image-text-section_image\" data-src=\"https:\/\/aircontech.eu\/wp-content\/uploads\/2024\/08\/fahrerkabine-3d-design.jpg\" data-srcset=\"https:\/\/aircontech.eu\/wp-content\/uploads\/2024\/08\/fahrerkabine-3d-design.jpg 800w, https:\/\/aircontech.eu\/wp-content\/uploads\/2024\/08\/fahrerkabine-3d-design-300x235.jpg 300w, https:\/\/aircontech.eu\/wp-content\/uploads\/2024\/08\/fahrerkabine-3d-design-768x601.jpg 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" alt=\"Fahrerkabine 3d-Design\" \/>\n      <\/div>\n\n      <div class=\"uk-width-1-2@m\">\n                <p>A critical area of thermal management in railway vehicles is the temperature control of batteries. Thermocontrol units monitor and regulate battery temperatures to maximise their performance and service life. Heat pumps, which can be used for both heating and cooling, are often used for this purpose, making them a flexible and efficient solution.<\/p>\n\n              <\/div>\n\n    <\/div>\n  <\/div>\n<\/section>\n<section style=\"background-color:#f5f5f5\" class=\"image-text-section\">\n  <div class=\"uk-container uk-container-large\">\n\n    <div uk-grid class=\"uk-flex uk-flex-middle\">\n      <div class=\"uk-width-1-2@m image-text-section_image uk-flex-last@m\">\n        <img uk-img=\"target: .image-text-section_image\" data-src=\"https:\/\/aircontech.eu\/wp-content\/uploads\/2025\/06\/hvac-kompaktsystem-schienenfahrzeuge.webp\" data-srcset=\"https:\/\/aircontech.eu\/wp-content\/uploads\/2025\/06\/hvac-kompaktsystem-schienenfahrzeuge.webp 1000w, https:\/\/aircontech.eu\/wp-content\/uploads\/2025\/06\/hvac-kompaktsystem-schienenfahrzeuge-300x300.webp 300w, https:\/\/aircontech.eu\/wp-content\/uploads\/2025\/06\/hvac-kompaktsystem-schienenfahrzeuge-150x150.webp 150w, https:\/\/aircontech.eu\/wp-content\/uploads\/2025\/06\/hvac-kompaktsystem-schienenfahrzeuge-768x768.webp 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" alt=\"HVAC Kompaktsystem Schienenfahrzeuge\" \/>\n      <\/div>\n\n      <div class=\"uk-width-1-2@m\">\n                <h3>Example of a Customer Solution<\/h3>\n<p><strong>Problem:<\/strong><br \/>\nCustomer request for an HVAC system for his track construction machine including the framework conditions to be considered (specifications). <\/p>\n<p><strong>Solution:<\/strong><\/p>\n<ul>\n<li>HVAC compact system \u21e8 load-bearing HVAC frame for the entire vehicle with KTL coating (including strength calculation).<\/li>\n<li>Pre-filled &#8220;Plug &amp; Play&#8221; solution \u21e8 a process-safe and cost-effective installation &amp; removal (for service) is possible by means of a heavy-duty rail.<\/li>\n<li>E-plate &amp; controller separated and connected to HVAC via quick-release connector.<\/li>\n<\/ul>\n\n                  <div class=\"uk-align-left\">\n            <a target=\"\" class=\"uk-margin-small-right uk-width-auto uk-button uk-button-primary button-normal\" title=\"Send request\" href=\"https:\/\/aircontech.eu\/en\/contact\">Send request<\/a>          <\/div>\n                <\/div>\n\n    <\/div>\n  <\/div>\n<\/section>\n<section style=\"background-color:var(--act-bgcolor2)\" class=\"cta-section\">\n    <div class=\"uk-container uk-container-large\">\n\n      <div uk-grid class=\"uk-flex uk-flex-center uk-flex-middle\">\n\n        <div class=\"uk-width-2-3@m cta-section_text uk-text-center\">\n          <p>Reliability and efficiency.<\/p>\n\n                      <div class=\"uk-flex uk-flex-center\">\n              <a target=\"\" class=\"uk-margin-small-right uk-width-auto uk-button uk-button-primary button-inverse\" title=\"Find out for free now!\" href=\"https:\/\/aircontech.eu\/en\/contact\">Find out for free now!<\/a>            <\/div>\n                    <\/div>\n\n      <\/div>\n    <\/div>\n<\/section>\n\n<section class=\"section-headline\">\n  <h2 class=\"section-headline_headline uk-display-inline\">Railway track construction machines<\/h2>\n<\/section>\n<section  class=\"image-text-section\">\n  <div class=\"uk-container uk-container-large\">\n\n    <div uk-grid class=\"uk-flex uk-flex-middle\">\n      <div class=\"uk-width-1-2@m image-text-section_image uk-flex-last@m\">\n        <img uk-img=\"target: .image-text-section_image\" data-src=\"https:\/\/aircontech.eu\/wp-content\/uploads\/2022\/08\/klima-kompaktanlage.jpg\" data-srcset=\"https:\/\/aircontech.eu\/wp-content\/uploads\/2022\/08\/klima-kompaktanlage.jpg 661w, https:\/\/aircontech.eu\/wp-content\/uploads\/2022\/08\/klima-kompaktanlage-300x209.jpg 300w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" alt=\"Klima-Kompaktanlage f\u00fcr Fahrerkabine bei Plasser &#038; Theurer | Aircontech\" \/>\n      <\/div>\n\n      <div class=\"uk-width-1-2@m\">\n                <p>Railway track construction machines are often used in extreme weather conditions and challenging environments. This requires specialised air conditioning systems that ensure the optimum ambient temperature for operators, which increases both productivity and safety. Efficient HVAC systems help to regulate the temperature in driver cabs and optimise working conditions.<\/p>\n\n              <\/div>\n\n    <\/div>\n  <\/div>\n<\/section>\n\n<section class=\"section-headline\">\n  <h2 class=\"section-headline_headline uk-display-inline\">Fire protection EN 45545<\/h2>\n<\/section>\n<section  class=\"text-section\">\n  <div class=\"uk-container uk-container-large\">\n\n    <div uk-grid>\n\n      <div class=\"uk-width-1-1\">\n        <p>Another important aspect of thermal management for railway vehicles is compliance with railway standards for fire protection, in particular EN 45545. This standard specifies the requirements for the fire behaviour of materials and components in railway vehicles. Thermal management systems must be made of materials that meet these strict fire safety requirements to ensure the safety of passengers and staff. Components such as cables, insulating materials and housings are designed to produce only minimal amounts of smoke or toxic emissions in the event of a fire.   <\/p>\n\n              <\/div>\n\n    <\/div>\n  <\/div>\n<\/section>\n<section style=\"background-color:#f5f5f5\" class=\"image-text-section\">\n  <div class=\"uk-container uk-container-large\">\n\n    <div uk-grid class=\"uk-flex uk-flex-middle\">\n      <div class=\"uk-width-1-2@m image-text-section_image uk-flex-first\">\n        <img uk-img=\"target: .image-text-section_image\" data-src=\"https:\/\/aircontech.eu\/wp-content\/uploads\/2025\/06\/hvac-splitsystem-gleisbaumaschine.webp\" data-srcset=\"https:\/\/aircontech.eu\/wp-content\/uploads\/2025\/06\/hvac-splitsystem-gleisbaumaschine.webp 1000w, https:\/\/aircontech.eu\/wp-content\/uploads\/2025\/06\/hvac-splitsystem-gleisbaumaschine-300x300.webp 300w, https:\/\/aircontech.eu\/wp-content\/uploads\/2025\/06\/hvac-splitsystem-gleisbaumaschine-150x150.webp 150w, https:\/\/aircontech.eu\/wp-content\/uploads\/2025\/06\/hvac-splitsystem-gleisbaumaschine-768x768.webp 768w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" alt=\"HVAC-Splitsystem Gleisbaumaschine\" \/>\n      <\/div>\n\n      <div class=\"uk-width-1-2@m\">\n                <h3>Example of a Customer Solution<\/h3>\n<p><strong>Problem:<\/strong><br \/>\nCustomer request for an HVAC system for his track construction machine including the framework conditions to be considered (specifications). <\/p>\n<p><strong>Solution:<\/strong><\/p>\n<ul>\n<li>For <strong>space reasons<\/strong>, an <strong>HVAC split system<\/strong> was developed. The evaporator (indoor unit) and condenser unit (outdoor unit) are installed separately. <\/li>\n<li>The specially developed hydraulic compressor is used. This is installed in the condenser unit. <\/li>\n<li>Robust stainless steel housing to meet the requirements, especially due to shock and vibration testing according to EN 61373-2019\/Cat.1-Class B, robustness and durability.<\/li>\n<\/ul>\n\n                  <div class=\"uk-align-left\">\n            <a target=\"\" class=\"uk-margin-small-right uk-width-auto uk-button uk-button-primary button-normal\" title=\"Send request\" href=\"https:\/\/aircontech.eu\/en\/contact\">Send request<\/a>          <\/div>\n                <\/div>\n\n    <\/div>\n  <\/div>\n<\/section>\n<section style=\"background-color:var(--act-bgcolor2)\" class=\"cta-section\">\n    <div class=\"uk-container uk-container-large\">\n\n      <div uk-grid class=\"uk-flex uk-flex-center uk-flex-middle\">\n\n        <div class=\"uk-width-2-3@m cta-section_text uk-text-center\">\n          <p>Operational reliability and performance.<\/p>\n\n                      <div class=\"uk-flex uk-flex-center\">\n              <a target=\"\" class=\"uk-margin-small-right uk-width-auto uk-button uk-button-primary button-inverse\" title=\"Find out for free now!\" href=\"https:\/\/aircontech.eu\/en\/contact\">Find out for free now!<\/a>            <\/div>\n                    <\/div>\n\n      <\/div>\n    <\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-3209","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/aircontech.eu\/en\/wp-json\/wp\/v2\/pages\/3209","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/aircontech.eu\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/aircontech.eu\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/aircontech.eu\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/aircontech.eu\/en\/wp-json\/wp\/v2\/comments?post=3209"}],"version-history":[{"count":10,"href":"https:\/\/aircontech.eu\/en\/wp-json\/wp\/v2\/pages\/3209\/revisions"}],"predecessor-version":[{"id":3825,"href":"https:\/\/aircontech.eu\/en\/wp-json\/wp\/v2\/pages\/3209\/revisions\/3825"}],"wp:attachment":[{"href":"https:\/\/aircontech.eu\/en\/wp-json\/wp\/v2\/media?parent=3209"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}